Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T08CM00299

Parcel: 11004343C

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
10/21/2008 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
SITE SCREEN WALL FOOTINGS (DETAIL #109)
BICYCLE PARKING SITE; FOOTINGS - DETAIL 4/X1.1
10/20/2008 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELED
08/12/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
WEST SCREEN WALL FOOTING - OK TO POUR (COMPLETE)
08/08/2008 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
WATER IN FOOTINGS
08/06/2008 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
1) CONTRACTOR CANCELLED-RAINED OUT
08/01/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
SITE WALL FOOTING (WEST) APPROX. 260 L.F
AS PER DETAIL #4; PAGE X1.1; OK TO POUR PROGRESS AREA
05/29/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
MAIN ENTRY AREA LINES A.1/5.1 TO B.3/6.1
FOOTINGS & INTERIOR COLUMN FOOTINGS (C.1/F.1, F2, F3)
OK TO POUR PROGRESS AREAS
05/23/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
CONTINUOUS FOOTINGS (F-1) (F-3); INTER COLUMNS (C1, F2)
OK TO POUR PROGRESS AREAS (F-3, F-4)