Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
03/14/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
03/06/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED TRUSS DRAWINGS
2) IS WALL GARAGE TO ENTRY BEARING ?, IF SO HOW FAR FROM VERT. MEMEBER CAN BEARING PT BE ?
3) VERIFY TRUSS A4 NOTCHING OF TOP CHORD WITHOUT WALL BELOW
4) NEED ST 2115 STRAPS EACH SIDE OF GARAGE HEADER 16" LONG 8 NAILS EACH
5) FRONT BEDROOM BEAM 4 X 6 SUPPORTING TRUSSES NOT ON PLAN
6) ALL SHEARWALLS AT PARALLEL WALLS ATTACH TO TRUSSES FOR DETAIL 10/DT1 NAIL SHEAR TO TOP PLATE