Permit: T08CM00277

Parcel: 110030270

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
03/31/2010 FRAMING Approved IVRS - Inspection :*
03/05/2010 FRAMING Partial Approval IVRS - Inspection :*
12/01/2009 FRAMING Partial Approval
11/25/2009 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL PROTECT KIT. SINK ABS AT BOTTOM PLATE
2) GROUND METAL BOXES
3) 2, 7 AND 8 ?
11/17/2009 FRAMING Partial Approval IVRS - Inspection :*
1) MAX 24" STUD AT FURNACE
2) DOES FURN GET AT CUT OFF SENSOR FOR 2ND CONDENSATE LINE ?
3) BANG PLATE, ALL PIPES, WIRES, NAIL PROTECTION CLOSER THAN 1 1/4" TO EDGES
4) GROUND ALL METAL BOXES
5) APPROVED FAN BOXES
6) FLOOR DECK 6 & 10 FASTENING 2 1/2" DECK SCREWS
7) NO LISTING ON FLEX DUCT R-8 INSUL. MIN
8) NAIL INTERIOR SHEAR 12" ON CENTER 16D/BOTTOM PLATE LSTA30 PAGE 149 SIMPSON 30" LONG 1 1/4 WIDE 22 10D'S
03/17/2009 FRAMING Not ready for Inspection IVRS - Inspection :*
1) FRAMING LOOKS OK BUT IS, DONE WITH INTERMEDIATE INSPECTIONS