Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/24/2009 | PLUMBING - ROUGH, SOIL | Approved | OK TO POUR MIDDLE SECTION | |
| 01/14/2009 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* UPPER LEVEL, BELOW SLAB SOIL PIPE BETWEEN COLS. K-T WITH TEST OK |
|
| 01/12/2009 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* FIRST FLOOR ROUGH IN CORRECTIONS MADE OK OK TO COVER WATER TEST, ONE RISER TO TEN FEET OK |
|
| 01/08/2009 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1. VERTICAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP 2. REQUIRE 2X THE PIPE DIAMETER BETWEEN TRAP WEIR AND POINT OF VENT 3. HORIZONTAL VENTING BELOW FLOOD RIM DUE TO STRUCTURAL CONDITIONS 4. OK TO COVER UNAFFECTED AREAS 5. RETEST AFTER CORRECTIONS MADE 6. TRAP SEAL DEPTH TO BE 2"-4" MAX. |
|
| 01/07/2009 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* YOU MAY NOT TEST PVC WITH AIR TEST PER PLAN SPECS, SEE PAGE MP1 |
|
| 01/02/2009 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) PLAN SEEMS TO BE MISSING ESSENTIAL INFORMATION IE. DWV MATERIAL TYPES, WATER SUPPLY, INSULATION, GAS, ETC... MATERIAL TYPES 2) CONTINUED NOT READYS MAY RESULT IN A REINSPECTION FEE |