Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T08CM00223
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/13/2009 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* | |
11/25/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
11/24/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* TRASH ENCLOSURE REINFORCEMENT STEEL @ FOOTING ON NORTH/EAST CORNER OK |
|
11/19/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* STEEL REINFORCEMENT @ SOUTHWEST EXTERIOR STAIRWAY |
|
11/14/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* SOUTHEAST ENTRY STAIRS |
|
11/13/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* WEST LOADING DOCK TRUCK RAMP & SUMPS S/W BLDG. CORNER ENTRY RAMP & STAIRS FOOTING |
|
11/12/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* REBAR @ MIDDLE & EAST NORTH SIDE LOADING DOCKS TRUCK RAMPS |
|
11/10/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* 1. WHICH BUILDING AM I SUPPOSED TO LOOK AT? 2. WHERE IS SUPER & WHAT IS HIS PHONE #? 3. LOADING DOCKS (IF THAT IS WHAT YOU WANTED) ARE NOT READY |
|
11/06/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* SOUTHWEST CORNER ENTRY, RAMP & STAIRS FOOTINGS OK TO POUR |
|
11/03/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
10/29/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 3 - CONCRETE DOCK SEPARATION WALLS FROM WEST TO EAST OK |
|
10/27/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. RETAINING ADJACENT TO SOUTH ENTRY WALL 2. POUR BACK 8.8 TO 9.1/C.8 TO D.1 |
|
10/23/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. EAST 3 LOADING DOCK WALLS 2. TERRACON SPECIAL INSPECTED |
|
10/21/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. RETAINING WALL FOOTING SOUTH OF BLDG. 4 6.5 TO 3.5 2. TO BE SPECIAL INSPECTED |
|
10/17/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* LOADING DOCK RETAINING WALLS AND RETAINING WALL AT WEST SIDE ENTRANCE |
|
10/15/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* D-9 TO 8 9-D TO C TERRACON SPECIAL INSPECTED |
|
10/14/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* CANCELED BY CONTRACTOR |
|
10/13/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. POUR BACK D-2 TO 3.5, D-4.5 TO 5.5, D 6.5 TO 8, 1-A TO C 2. FOOTING 1.2 - A TO A.2 A-1 TO 1.2 3. MAINTAIN REBAR CLEARANCE TERRACON SPECIAL INSPECTED |
|
10/10/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* BLDG. #4 CLOSURE POUR NOT COMPLETE |
|
10/08/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. POUR BACK A-1 TO 4.5, 8.5 TO 9, 9-A TO C 2. TERRACON SPECIAL INSPECTED |
|
10/07/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* POUR BACK BLDG. 4 A-4.5 TO 8.5 SPECIAL INSPECTED |
|
10/06/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
09/19/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
08/22/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. PANELS 93, 94, 119, 120, 121, 122, 123, 124, 125, 126, 127, 128, 129, 130, 130B, 131, 132, 133, 134 2. FOOTINGS D-.9 TO 9.1/.09-B.5 TO D 3. SPECIAL INSPECTED BY TERRACON 4. #4 GROUND WIRE CONNECTED TO 20' CONTINUOUS REBAR WITH 2 SEPARATE LUGS TIGHT |
|
08/21/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* FOOTINGS F3, F4, F2 LINE 1 A TO B8 LINE A - 1 TO 9 |
|
08/19/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. F4 & F1 FOOTINGS A TO C 9.1 2. F8 & F9 COLUMN FOOTINGS 5 AT SW CORNER 3. PANELS 97, 98A, 98B, 99 AND 91, 96 WITH SPECIAL INSP. |
|
08/18/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
08/12/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* PANELS 101, 103, 104, 107, 108 TERRACON SPECIAL INSPECTION |
|
08/11/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* CANCELED BY CONTRACTOR |
|
08/08/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* PANELS 100, 102, 105 -- OK TO POUR TERRACON SPECIAL INSPECTED |
|
08/07/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1) TILT PANELS 106, 109, 110 OK TO POUR |
|
08/06/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1) PANELS 106, 109, 110 & 111 2) NEED CLARIFICATION DOES TYP REINFORCING ? FROM PANEL EDGE TO EDGE |
|
08/05/2008 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* REBAR NOT TIED |
|
08/01/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* PANELS 83, 84, 87, 88, 95, 92 REQ. SPECIAL INSPECTION |
|
07/30/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* OK TO POUR PANELS 78, 79, 80, 81, 82, 85, 86, 89, 90, 117, 118 1. TERRACON SPECIAL INSPECTION |
|
07/29/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* CANCELED BY CONTRACTOR |
|
07/24/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* TILT PANELS 12, 113, 114, 115, 116 SPECIAL INSPECTED TERRACON |
|
07/23/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
06/20/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* ALL CP2 ON LINE C.8 S5.1 (117) SPECIAL INSPECTED |
|
06/16/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 16 EXT. COLUMN FOOTINGS SOUTH 2 UP ON LINE 1 & 9 TERRACON SPECIAL INSPECTED |
|
06/13/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* INTERIOR COLUMNS SPREAD FOOTINGS B/2,3,4,5,6,7,8 C/2,3,4,5,6,7,8 OK TO POUR TERRACON INSPECTED |