Permit: T08CM00216

Parcel: 141096710

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T08CM00216

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
02/27/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
02/22/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSED 3 SHEARWALLS 3 TOTAL FOR STIFFNESS
2) MISSED #4 GOES CONTINOUS UP TO 2ND FLOOR
3) 2 ROWS OF CS20 STRAPS AT 1ST FLOOR ABOVE/BELOW 2ND 1 ROW
4) REAR HEADERS EACH SIDE OF SLIDING DOOR NOT PER PLAN
5) NEED 3 1/8 X 9 GLUE LAM AT FRONT ENTRY
6) SHEAR TRANSFER DETAIL WALL TO TRUSS NOT PER PLAN LADDER BLOCKS NOT SHOWN 5/D3 SOLID 2 X ON TOP OF PLATE
7) #4 INTERIOR SHEAR REQUIRED F STRAP EACH END OF SHEAR 31" PLUS CLEAR SPAN (DEPTH OF FLOOR)