Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T08CM00213
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/17/2008 | FRAMING | Approved | IVRS - Inspection :* | |
04/15/2008 | FRAMING | Partial Approval | IVRS - Inspection :* 1) A01P TRUSS SHOP DRAWING, DOES NOT MATCH INSTALLATION AND DRAWING SHOWS PORCH OPTION WITH 3 PT BEARING, PROBABLY AN OLD TRUSS DRAWING TRUSS IS SYMETRICAL, NO VERTICAL MEMBER FOR 3 PT BEARING AT EITHER END-PLEASE VERIFY |
|
04/11/2008 | FRAMING | Partial Approval | IVRS - Inspection :* 1) PLEASE LEAVE TRUSS DRAWINGS, CHECK A02 TRUSSES AT MASTER ENTRY, FOR 3 PT BEARING 2) SMAIL SCISSOR TRUSS OVER FRONT WINDOW INTERIOR BEARING ANDD BLOCKS FOR BEARING BELOW AND IN BETWEEN WEB 3) SHIM AND NAIL SHEAR TRANSFERS INT. SHEARWALLS AT TOP PLATE GAP 4) 5/SD? BLOCK AND NAIL TRANSFER TO DRAG TRUSS |
|
03/26/2008 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) FINISH ALL TRADES 2) STUCCO LATH NOT STARTED YET |