Permit: T08CM00213

Parcel: 141096360

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T08CM00213

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
04/17/2008 FRAMING Approved IVRS - Inspection :*
04/15/2008 FRAMING Partial Approval IVRS - Inspection :*
1) A01P TRUSS SHOP DRAWING, DOES NOT MATCH INSTALLATION AND DRAWING SHOWS PORCH OPTION WITH 3 PT BEARING, PROBABLY AN OLD TRUSS DRAWING TRUSS IS SYMETRICAL, NO VERTICAL MEMBER FOR 3 PT BEARING AT EITHER END-PLEASE VERIFY
04/11/2008 FRAMING Partial Approval IVRS - Inspection :*
1) PLEASE LEAVE TRUSS DRAWINGS, CHECK A02 TRUSSES AT MASTER ENTRY, FOR 3 PT BEARING
2) SMAIL SCISSOR TRUSS OVER FRONT WINDOW INTERIOR BEARING ANDD BLOCKS FOR BEARING BELOW AND IN BETWEEN WEB
3) SHIM AND NAIL SHEAR TRANSFERS INT. SHEARWALLS AT TOP PLATE GAP
4) 5/SD? BLOCK AND NAIL TRANSFER TO DRAG TRUSS
03/26/2008 FRAMING Not ready for Inspection IVRS - Inspection :*
1) FINISH ALL TRADES
2) STUCCO LATH NOT STARTED YET