Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T08CM00210

Parcel: 141096350

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T08CM00210

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
03/05/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
02/27/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TO MANY SHINNERS, ON TOP OF ROOF DECK ROUND DOWN FLUSH
2) USE 16D NAILS AT HANGERS FRONT ENTRY
3) FILL IN GAP AT REAR GABLE TRUSS TO TOP PLATE