Permit: T08CM00209

Parcel: 141096340

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Permit Number - T08CM00209

Inspection Description - EXCAVATION/LAYOUT REBAR & ZON

Inspection Status - Approved

Date Description Inspector Results Comments
02/13/2008 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
02/12/2008 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) HORIZ BAR TO HIGH AT GARAGE PERIMETER 1 1/2" OF COVER REQUIRED
2) AT EAST SIDE ENTRY START BAR LAYOUT AT 18" THEN 18" ON CENTER
3) WEST SIDE STEEL TO HIGH AT TUB BLOCK OUT
4) REAR SHOWER STEEL NOT SUPPORTED ON GROUND
5) SUPPORT REBAR AT GARAGE WINGS