Permit: T08CM00199

Parcel: 133146610

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
02/05/2008 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
WILL CHECK CONNECTION TO VENT ABV CEILING AT FINAL
02/04/2008 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 2" WCO SPECIFIED FOR SINKS PER YOUR PLAN
2) REMEMBER TO INSTALL CLEANOUT ABOVE FLOW LINE
01/31/2008 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
- DOUBLE FIXTURE FITTING REQUIRED AT BACK TO BACK FIXTURES.
- ALSO, REMOVE ABS MELTED BY SOLDERING
- SUPPORT ABS AND SECURE W/APPROVED PIPE SUPPORT, AND KEEP AWAY FROM SHARP METAL STUD
- WIPE OFF EXCESS FLUX