Permit: T08CM00194

Parcel: 141351630

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T08CM00194

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
04/02/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
04/01/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
- RETRO HOLD DOWN ON FRONT GARAGE WALL OVERHEAD EAST SIDE
03/19/2008 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) OK TO COVER EXT. WALLS
03/18/2008 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) GARAGE FRONT SHEAR EAST OVER SPAULED P.A.
2) NEED MIN 2 1/2 DIAMETER A.B.'S EACH SIDE
3) MISSING A.B.'S AT KIT. SHEAR INTERIOR
4) A.B.'S AT EXT. PLATE SPLICES
5) WRONG HANGERS INSTALLED AT ROOF USE HUS TYPE 1517 16'S WITH 16D TECO .162 DIAMETER
03/17/2008 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) CANCELLED NOT READY
03/14/2008 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*