Permit: T08CM00170

Parcel: 136290020


Addresses:

3951 S PANTANO RD


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T08CM00170

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
03/26/2009 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
COMPLETED BRICK COLUMNS @ NORTH SIDE OF BLDG.
03/02/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TAPERED M-Z COLUMN 6' NORTH OF NEC OF RM. #100
TO 16'7"
A TO F - SPECIAL INSPECTED OK
02/25/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU EXTERNAL COLUMNS @ NORTH SIDE OF GYM BLDG. FROM 0' TO 4' A TO F AND 3 CMU FROM NE CORNER OF GYM TO THE WEST FROM 4' TO 8' ABOVE TOP OF FOOTING - OK
SPECIAL INSPECTED
02/20/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU REINFORCEMENT @ NORTH WALL ROOM #201 TOP OUT AND ALL STAIRWAY WALL TOPOUT
02/18/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALLS @ NORTH WALL OF MEZZANINE FROM 24' TO 28'8" WEST AND SOUTH WALLS OF STAIRWELL @ MEZZANINE
FROM 20' TO 24'0" & 12" CMU RETAINING WALL @ SEC.
FROM 0" TO 2'0" AFFE - SPECIAL INSPECTED
02/12/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) CMU WALL REINFORCEMENT AT SOUTH AND WEST STAIRWAY WALLS FROM 18' TO 20'-NORTH WALL ROOM #201 FROM 20' TO 24' AND EAST STAIRWAY WALL FROM 20" TO 24' AFFE SPECIAL INSPECTED
02/11/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALL REINFORCEMENT @ EAST STAIRWELL WALL FROM 16'8" TO 20'8" AFFE AND SOUTHWEST STAIRWELL WALL FROM 14'8" TO 18'8" AFFE -- SPECIAL INSPECTED
02/10/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALL REINFORCEMENT AT NORTH WALL OF
ROOM #201 FROM 16' TO 20' AFFE -
SPECIAL INSPECTION BY WESTERN TECH.
01/29/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALL REINFORCEMENT @ EAST WALL RM.#202
FROM 28' TO 32'8" - NWC RM. #100 FROM 12'8" TO 15'4" -
EAST WALL RM. #202 FROM 24'8" TO 28'8" AND
ROOM #202 32'8" TO 35'4" AFFE --
SPECIAL INSPECTION PERFORMED
01/28/2009 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
01/27/2009 REINFORCED MASONRY PRE-GROUT Denied IVRS - Inspection :
See detailed listing on site.| 999*
PLEASE HAVE SPECIAL INSPECTOR ANDREWS & CITY INSPECTOR DABBS CALL ME ABOUT DETAIL T26 MCJ SPLICES AND CONDUITS IN GROUT CELLS
01/26/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALL REINFORCEMENT @ EAST WALL OF TREATMENT ROOM #104 -- TOP OUT -- SPECIAL INSPECTION PERFORMED
01/22/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU REINFORCEMENT STEEL @ N/W PIER
COLUMN & EAST WALL RM.#104 FROM 8' TO 12' AFFE
EAST WALL RM. #100
TOP OUT - NORTH WALL N/W CORNER RM. #104 TO 14
END FROM 14' TO 16' AND WEST WALL OF RM. #104 FROM
16' TO 20'8" AFFE - SPECIAL INSPECTION PERFORMED
01/21/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALL REINFORCEMENT @ EAST WALL RM. #100
FROM 24'8" TO 32' AFFE
O' NORTH 26'/0' WEST 6' WEST OF SEC. RM. #102 4'8" TO 8'8" AND COLUMN NWC RM. #100 TO 4'8" AFFE
01/20/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALL REINFORCEMENT @ EAST WALL ROOM #100
FROM 20'8" TO 24'8" AFFE
WEST WALL ROOM #100 FROM 12' TO 16' (INCLUDES BOTH WING WALLS - WEST WALL RM. #104 FROM 17'4" TO 20' AFFE
0' TO 26' NORTH SEC. RM. #102, 0' W - 6' W OF SEC. RM. #102 AND COLUMN @ NWC RM. #100 FROM 0' TO 4'8" AND W.WALL RM. #110 8' TO 10' AFFE -- OK TO GROUT
01/15/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALL REINFORCEMENT AT FOLLOWING LOCATIONS:
EAST WALL RM. #105 FROM 0' TO 17' NORTH OF GYM WALL
FROM 13'4" TO 17'4" AFFE & FROM 17' TO 23' NORTH OF GYM WALL FROM 13'4" TO 15'4" AFFE AND
FROM 0' TO 9' SOUTH/0' TO 24' WEST OF HYDRO 107 FROM 13'4" TO 17'4" AFFE SPECIAL INSPECTED
01/13/2009 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL REINFORCEMENT AT FOLLOWING LOCATIONS:
EAST WALL ROOMS #100 FROM 16'8" TO 20'8" AFFE
EAST WALL RM. #110 FROM 12'8" TO 13'8" AFFE (TOP OF WALL)
EAST WALL RM. #108 FROM 12'8" TO 16'8" AFFE AND WEST WALL RM. #100 FROM 8'8" TO 12'8" AFFE - SPECIAL INSPECTED
01/12/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALL REINFORCEMENT @ LOBBY WEST WALL TO 8'8"
ROOM #104 N/E CORNER TOP OUT AND EAST & WEST
WALLS @ RM.#108 CONTINUED -- OK
SPECIAL INSPECTED
01/12/2009 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL REINFORCEMENT AT FOLLOWING LOCATIONS
WEST WALL RM. #100 FROM 4'8" TO 8'8" AFFE
EAST WALL RMS. #108 & 110 FROM 8'8" TO 12'8" AFFE
WEST WALL RM. #110 FROM 0' TO 4'8" AFFE
EAST WALL AT ROOMS #105 & 107 FROM 8'8" TO 13'4" (INCLUDES MASONRY LENTEL) AFFE
AND NORTH WALL RM.#104 FROM 12'8" TO 17'4" AFEE TOP OUT "SPECIAL INSPECTED"
01/09/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALL REINFORCEMENT AT S,W & N WALLS IN ROOMS #100 FROM 0 TO 4:7 - E WALLS RM. #108, 110,
WEST WALL RM. #104 FROM 4.7' TO 8.7' AFFE
SPECIAL INSPECTED
01/08/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALL REINFORCEMENT STEEL @ W.WALL RMS. #105, 106, 107 FROM 0' TO 4'8" - N.WALL @ RMS. #107, 108, 109, 114 & 115
FROM 12'8" TO 14'0" - E.WALL @ RMS. #112 & 115 FROM 12'8" TO 16'8" AND INT. WALLS @ RMS. 111, 112, 113, 114 AND 115
TOP OUT AFFE (SPECIAL INSPECTED)
01/06/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALL REINFORCEMENT @ NEC ROOM #100
NEC RM. #104 - EAST WALL ROOM #100; EAST WALL RM. #112
NORTH & SOUTH WALLS RM. #113;
EAST & SOUTH WALLS RM. #114
WEST & SOUTH WALLS RM. #108 FROM 8'8" TO 12'8" AFFE AND EAST WALL RM. #105 FROM 8'8" TO 10' AFFE
01/05/2009 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
RAINED OUT
12/30/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) NORTH AND EAST CMU WALLS AT #106 STAIRS AND NORTH & EAST CMU WALLS AT ROOM #104 FROM 8'-8" TO 12'-8" OK TO GROUT SPECIAL INSPECTED
12/24/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU MASONRY WALL @ GRID
EAST WALL ROOM #104 0' TO 5'4" S. OF NEC. S WALL ROOM #104, EAST WALL ROOM #105 0-4.7 AFFE - WEST WALL ROOMS #112 AND 115, NORTH WALL ROOM #115, 114, 109, 108
S & E WALLS ROOM #114 - SE WALLS ROOM #113
EAST WALL ROOM #108 FROM 4'7" TO 8'7" AFFE
12/23/2008 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELED RAINED OUT
12/18/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
ROOMS #102 THRU #115 FROM 0' TO 4'8" & ROOM #108 EAST AND SOUTH CMU WALL FROM 4'8" TO 8'8" -- OK TO GROUT
SPECIAL INSPECTED
12/17/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALL REINFORCEMENT @ SOUTH ENTRY
INFILL 10' WEST TO 32' WEST @ S/E CORNER OF GYM
AND SOUTH WALL OPENING 4'8" TO 8'8"
12/16/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SOUTH ENTRY INFILL FROM 12' TO 16' OK
12/15/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALL REINFORCEMENT @ ROOMS #113 ALL FOUR WALLS; ROOM #109 ALL WALLS EXCEPT NORTH WALL AND ROOMS #114 & 119 ALL EXCEPT NORTH WALL FROM 0' TO 4'8"
OK TO GROUT -- SPECIAL INSPECTED
12/12/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SOUTH ENTRY INFILL OF CMU -- 2ND LIFT FROM 4'0" TO 8'0"
OK TO GROUT
12/11/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SOUTH CMU MASONRY INFILL @ ENTRY CLOSURE
08/22/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
GYM BUILDING CMU TOP OUT COMPLETE - EXCEPT ACCESS OPENING @ S/E CORNER OF SOUTH WALL
08/20/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH GYM CMU WALL FROM 28'8" TO 32'8" AFFE
AND FOUR CONCRETE 24" DUCT OPENINGS @ NORTH GYM CMU WALL
08/15/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH CMU GYM WALL FROM 24'8" TO 28'8" -- OK
08/13/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH CMU GYM WALL TO 24'8" WEST HALF
08/12/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. TOP OUT @ SOUTH CMU WALL
2. 25' @ EAST HALF OR NORTH CMU WALL AND 20'8" @ WEST HALF OF NORTH CMU WALL
08/08/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. SOUTH CMU EXTERIOR WALL 7TH LIFT FROM 24'8" TO 28'8"
2. NORTH CMU WALL EAST 1/2 TO 16'8" 4TH LIFT
08/06/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) CMU WALL AT NORTH SIDE 4TH LIFT TO 16'-OK TO GROUT
08/05/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALLS
1. EAST WALL 6TH LIFT TO 24'8"
2. WEST WALL WINDOW COLUMNS 7TH LIFT TO 28'8" AND NORTH WALL @ N/W CORNER - 4TH LIFT TO 16'8"
OK TO GROUT
08/01/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
25' (TOP) WEST WALL AND 24'8" SOUTH WALL
07/30/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
ALL CMU EXTERIOR GYM WALLS TO 20'8"
EXCEPT @ TRIPLE DOOR LINTEL ON NORTH WALL @ WEST CORNER - OK TO GROUT
07/28/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
OVER DOORS 101D & E TO 16'8"
CMU EXTERIOR GYM WALLS, WEST WALL, FIRST 60 L.F
ON EAST WALL FROM SOUTHEAST CORNER NORTH AND
FIRST 13 L.F OF SOUTH WALL FROM S/E CORNER FROM
16'8" TO 20'8" AFFE
07/24/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH CMU GYM WALL FROM N/E CORNER 68' WEST TO 12'8" EAST WALL TO 16'8" & SOUTH WALL ABOVE DOORS #101D AND #101E TO 12'8" -- OK TO GROUT
07/23/2008 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
RAINED OUT
CONTRACTOR CANCELED
07/21/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU GYM WALLS 4TH LIFT FROM 12' TO 16' @ WEST, SOUTH AND EAST WALL TO FIRST CONTROL JOINT OFF SOUTH/EAST CORNER AND 3RD LIFT FROM 8' TO 12' @ BALANCE OF
EAST WALL
07/18/2008 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELED BY PHONE
07/17/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
3RD LIFT @ 12 FOOT - 8 INCH ON WEST & SOUTH WALLS
PLUS FIRST 20 L.F FROM S/E CORNER AND
2ND LIFT @ BALANCE OF EAST CMU WALL AND
NORTH CMU WALL TO 8'8" AFFE
07/16/2008 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELED BY PHONE
07/15/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
WEST AND SOUTH CMU WALLS AT GYM BUILDING 2ND LIFT
TO 8 FOOT 8 INCH -- OK TO GROUT
07/10/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
4' GYM PERIMETER