Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T08CM00145
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/05/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
03/04/2008 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) NEED ENGINEER FIX FOR RAFTER ABOVE STAIRS 2) FINISH RETRO WITH EQUIVALENCY PAPERWORK |
|
03/03/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TRUSS FIX STILL NEEDED 2) DBL STUD NEEDED FOR HOLDOWN IN FRONT FOYER WITH EQUIVALENCY PAPERWORK |
|
02/29/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 2 RETRO'S NEEDED BY FRONT DOOR FOR HOLDOWNS MISSED 2) SHEAR PANELS IN FLOOR TRUSSES ABOVE KITCHEN SINK TO BE NAILED THRU FLOOR 3) BLOCK FOR ? STRAP ON EAST SIDE TO SHORT IN TALL WALL 4) TRUSS FIX FOR BROKEN GUSSET ON 56D1 5) RED HEAD ANCHORS THRU OUT |