Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T08CM00144
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/04/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
03/03/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHINERS IN HOLDOWNS IN GARAGE WING WALL 2) NAIL OFF LEDGER ABOVE OVERHEAD DOOR OPENING TO BEAM 3) COIL STRAP WEST SIDE BELLY BAND 4) NAIL GABLE END BOTTOM CHORDS 5) FINISH SHEAR AT SOUTHEAST CORNER 6) COIL STRAP SHEAR AT FRONT OF HOUSE PER 518 DETAIL 7) NAIL OFF FLOOR SHEATHING ABOVE GARAGE 8) HOLDOWNS AND ANCHORS THRU OUT 9) STOPPED INSPECTION |