Permit: T08CM00141

Parcel: 141282920

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
07/10/2013 ROOF NAILING Approved IVRS - Inspection :*
07/09/2013 ROOF NAILING Cancelled IVRS - RI canceled
09/09/2008 ROOF NAILING Partial Approval 1) LARGE HANGER HU5.125/12 SIMPSON CALLS FOR 16D NAILS (22) INSIDE FLANTE, 16D BOX GAV USED NEED A CALC. FOR LOAD (2,950 LBS) WILL CARRY IF COMMONS USED
2) CONNECTION FLOOR JOIST TO LEDGER, OSB NOT TIED TOGETHER, CAN SCREWS BE USED IN HANGER FLANGE FOR WITHDRAWL
3) DON'T USE 8D'S IN LUS28 HANGERS, SIMPSON CALLS FOR MIN. 10D
4) LEDGER LAGS TO BE AT 16 ON CENTER