Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
Permit Number - T08CM00113
Inspection Description - MECHANICAL - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/04/2008 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* | |
| 05/21/2008 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PROVIDE INSTALLATION INSTRUCTIONS FOR FAN COILS 2. PROVIDE HOSE CLAMPS ON CONDENSATE HOSE 3. PROVIDE CAP ON LINE SET ROOF PENETRATIONS 4. ALL PVC IS TO BE PRIMED AND GLUED AT ALL JOINTS 5. ALL PVC EXPOSED TO U.V IS TO BE PROTECTED (PAINTED) 6. PVC DRAIN IS TO BE MIN. 1" PIPING DOWN TO FLOOR SINK 7. USE APPROVED METHODS TO TERMINATE COPPER INTO PVC |