Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T08CM00068
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/04/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
02/01/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SINK MISSING CLIPS IN FRONT & BACK INSTALL ALL CLIPS SUPPLIED W/SINK 2. ONLY ONE SLIP NUT ALLOWED DN STREAM OF TRAP 3. PROVIDE A CO PLUG W/A FACTORY TAP, ALL PLUMBING PARTS SHALL BE LISTED FOR THE USE INTENDED 4. PLAN SPECIFIES CLEVIS HANGERS |