Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T08CM00064
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/17/2008 | FRAMING | Approved | IVRS - Inspection :* | |
03/14/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIRESTOP STUD CAVITY WEST GARAGE WALL WITH BLOCK 2) DRAFTSTOP DUCT THROUGH GARAGE FIREWALL IN TRUSSES 3) ANCHOR BOLTS NEEDED ON SHEARWALLS PER PLAN 4) LATTERAL BRACE CUT IN KITCHEN CEILING AND HALL 5) SEAL PENETRATIONS 6) FINISH MESH 7) WIRES HANGING FROM HALL CEILING 2ND FLOOR 8) NAIL PROTECT WIRES SOUTHEAST CORNER MASTER BEDROOM 9) MIN 12" CLEARANCE FOR PEX TO RECESSED LIGHT IN HALLWAY FROM GARAGE 10) NAIL PLATES TO PROTECT A COIL LINE IN WEST WALL TO BE FILLED WITH 16D NAILS IN ALL HOLES |