Date Description Inspector Results Comments
03/17/2008 FRAMING Approved IVRS - Inspection :*
03/14/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FIRESTOP STUD CAVITY WEST GARAGE WALL WITH BLOCK
2) DRAFTSTOP DUCT THROUGH GARAGE FIREWALL IN TRUSSES
3) ANCHOR BOLTS NEEDED ON SHEARWALLS PER PLAN
4) LATTERAL BRACE CUT IN KITCHEN CEILING AND HALL
5) SEAL PENETRATIONS
6) FINISH MESH
7) WIRES HANGING FROM HALL CEILING 2ND FLOOR
8) NAIL PROTECT WIRES SOUTHEAST CORNER MASTER BEDROOM
9) MIN 12" CLEARANCE FOR PEX TO RECESSED LIGHT IN HALLWAY FROM GARAGE
10) NAIL PLATES TO PROTECT A COIL LINE IN WEST WALL TO BE FILLED WITH 16D NAILS IN ALL HOLES