Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T08CM00056

Parcel: 12713078B


Addresses:

6061 E BROADWAY BL


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T08CM00056

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
04/15/2008 ELECTRIC - FINAL Approved IVRS - Inspection :*
03/24/2008 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
WAITING ON SUITE #
03/20/2008 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
1. VDV CABLING TO BE AS PER 725.3 & 6, 800.3 & 24, 300.11
2. REMOVE BACK TO LAST JUNCTION BOX
3. PLEASE ADD A SUITE NUMBER TO PERMIT