Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
Permit Number - T08CM00039
Inspection Description - PLUMBING - SEWER HCS CONNECT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/15/2008 | PLUMBING - SEWER HCS CONNECT | Approved | IVRS - Inspection :* DO NOT ALLOW ANY DISCHARGE INTO MAIN SEWER UNTIL YOU HAVE RECEIVED AUTHORIZATION TO DISCHARGE FROM PCDEQ |
|
| 08/11/2008 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* HCS CONN TO EXISTING GYM OK BACKFILL W/CLEAN FILL KEEP ROCKS OFF PIPING |
|
| 08/08/2008 | PLUMBING - SEWER HCS CONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* AM INSP. REQ. 8:50 AM BACKPITCH ON PIPING AT TWO WAY C.OL 9:10 INSTALLER UNABLE TO CORRECT AT THIS TIME RECALL FOR INSP. 1/4" PER FOOT SLOPE REQUIRED |
|
| 08/07/2008 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection :* 1) 4" DIP FROM EXISTING BLDG TO EXISTING CLAY SADDLE TAP WITH 10' WATER TEST 2) PROVIDE DOCUMENTATION OF MATERIAL USED AND RECALL INSPECTION FOR CONN TO BLDG 3) DOWL ENGINEERING ON SITE |
|
| 08/06/2008 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* | |
| 08/05/2008 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection :* |