Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING PRE-SLAB
Permit Number - T08CM00039
Inspection Description - BUILDING PRE-SLAB
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/23/2009 | BUILDING PRE-SLAB | Approved | IVRS - Inspection :* SPECIAL INSPECTION LISTED AS NON-COMPLIANT; ENGINEERING (TLCP) FIRM TO VERIFY WIRE MESH LIFTED DURING SLAB POUR NON-USE OF CHAIRS TO SUPPORT WIRE MESH: OK TO POUR |
|
| 01/16/2009 | BUILDING PRE-SLAB | Partial Approval | GYM FLOOR SLAB #101 - OK TO POUR | |
| 12/11/2008 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* NORTH PORTION -- ALL AREAS EXCEPT PRACTICE GYM #101 OK TO POUR PROGRESS AREAS |