Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/26/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* CLOSET FLANGES OK FOR VINYL FLOORING |
|
| 06/16/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. TRAP PRIMER FOR ADDED FLOOR SINK IS A GRAVITY DRAIN TO FLOOR SINK AND NEEDS TO BE INSTALLED CORRECTLY. 2. THE GREASE TRAP ON THIS SITE IS AN UNSANITARY CONDITION THAT NEEDS TO BE CORRECTED WITH CORRECT DRAINAGE AND VENT FOR FLOW CONTROL FITTING. 3" WAS INSTALLED FOR DRAINAGE AT ROUGH SOIL INSPECTION AND WE NEED CITY APPROVED PLAN SHOWING SOMETHING FOR THIS. 3. PROVIDE PERMANENT CAP FOR 2 X 2 X 1 1/2 SANTEE ON 2" DRAINAGE FOR LAV IN WOMENS RESTROOM 4. CLOSET FLANGES ARE REQUIRED TO BE SECURED TO FLOORING MATERIAL WITH INSPECTION PRIOR TO INSTALLING STOOLS |