01/19/2010 | GRADING - TIER REV | Approved | ALL INSPECTIONS AND ANY CHANGES TO SITE/GRADING WORK WILL BE DOCUMENTED UNDER PERMIT#T09BU01550. ALL COMMENTS REGUARDING STORM WATER COMPLIANCE WILL ALSO BE ADDRESSED UNDER THE NEW PERMIT. | |
09/03/2009 | GRADING - TIER REV | Violation | A STOP WORK ORDER WAS ISSUED DUE TO THE FACT THAT WORK IS BEING ACCOMPLISHED NOT SHOWN ON UNDER THE CURRENT GRADING PERMIT AND APPROVED GRADING PLAN. THE CONTRACTOR MUST OBTAIN A PERMIT AND APPROVED GRADING PLAN PRIOR TO THE REMOVAL OF THE STOP WORK. |
|
08/03/2009 | GRADING - TIER REV | Continued | CHANGE TO DRAINAGE IN PARKING LOT: CONTRACTOR IS INSTALLING 200 + FEET OF 36" RCP AND ANOTHER 100 + FEET SECTION 3' X 6' BOX CULVERT, THREE CATCH BASINS AND A CONCRETE VALLEY GUTTER TO HANDLE SURFACE SHEET FLOW OF STORM WATER ON PROPERTY. CONTRACTOR SUBMITTED THE PLANS FOR THE REVISION AN IS AWAITING APPROVAL. |
|
05/07/2009 | GRADING - TIER REV | Correction Required | 1. SIDEWALK SCUPPERS REQUIRED FOR STORMWATER DRAINAGE BENEATH SIDEWALKS AND PEDESTRIAN WALKWAYS. 10 YEAR RAIN EVENT DISCHARGE MUST FLOW BENEATH SIDEWALKS SEE C.O.T. DEVELOPMENT STANDARD 2-08.3.1, 3-01.4.4.F, AND 2-08.5.1.F. 2. PREVIOUSLY GRADED PARKING LOT AND EQUIPMENT STORAGE AREAS AT NORTHWEST END OF SITE ARE BEYOND THE CONSTRUCTION LIMITS IDENTIFIED FOR THIS PROJECT. REVISED AND C.O.T. APPROVED PLANS ARE REQUIRED FOR THIS AREA. |