Inspection Status: Approved
Inspection History: POOL/SPA FINAL/BARRIER
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/09/2009 | POOL/SPA FINAL/BARRIER | Approved | IVRS - Inspection :* | |
| 02/04/2009 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999* GATES NEED TO BE SELF-CLOSING AND LATCHING |
|
| 01/28/2009 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999* SVRS S/N 047581 1. THERE MUST BE A BARRIER SOMEWHERE ON THE PROPERTY MINIMUM 5' HIGH WITH ALL GATES OPENING OUT AND SELF-CLOSING AND LATCHING 2. BARRIER BETWEEN HOUSE AND POOL MUST BE MINIMUM 4' HIGH WITH GATES SELF-CLOSING AND LATCHING. LATCH AT LEAST 54" HIGH 3. BARRIER MUST BE AT LEAST 20" FROM WATERS EDGE |