Permit: T08BU01538

Parcel: 11612751A


Addresses:

550 N SILVERBELL RD

Inspection Status: Continued

Inspection History: STORMWATER FINAL INSPECTION

Date Description Inspector Results Comments
12/04/2009 STORMWATER FINAL INSPECTION Continued 1) HC PARKING DOES NOT MEET ADAAG/ANSI REQ:
a) SLOPES NO >2% IN ANY DIRECTION
b) HC SURFACE MUST BE FIRM AND SLIP RESISTANT
c) INSTALL TRUNCATED DOMES AT ALL HC PARKING LOADING/UNLOADING AREAS.
2) INSTALL 6"x 6" EXTRUDED CURB (SEE NOTE #15) AS SHOWN ON PLANS
3) PROVIDE MANUFACTURES SPECS ON SOIL AMENDMENT USED.
4) PROVIDE STRIPING AT PARKING SPACES 9' APART AS SHOWN ON PLANS
12/04/2009 STORMWATER FINAL INSPECTION Continued CALLED IN FOR FINAL GRADING, NO CONTACT ON SITE.
OWNER/CONTRACTOR HAS NOT PROVIDED A STORM WATER PLAN FOR CONSTRUCTION AND AN APPROVED GRADING PLAN. SITE IS OCCUPIED