Inspection History Details
Inspection Status: Continued
Inspection History: GRADING - FINAL
Permit Number - T08BU01201
Inspection Description - GRADING - FINAL
Inspection Status - Continued
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/28/2010 | GRADING - FINAL | Continued | SITE STILL INCOMPLETE AT THIS TIME ON THE EAST AND WEST PADS. | |
07/30/2009 | GRADING - FINAL | Partial Approval | THE SITE HAS NOT CHANGED MUCH SINCE THE PREVIOUS INSPECTION. COMPLETE ALL OF THE WORK ON THIS SITE AND STABALIZE ALL AREAS NOT BEING COMPLETED AT THIS TIME PRIOR TO REQUESTING ANOTHER INSPECTION. ALL MISSING ITEMS PREVIOUSLY NOTED WILL HAVE TO BE ADDRESSED TO OUR REVIEWING STAFF BY THE ENGINEER OF RECORD PRIOR TO US ACCEPTING THEM AS AS-BUILT CONDITIONS. | |
07/28/2009 | GRADING - FINAL | Partial Approval | THE SITE WAS CHECKED AND MOST OF THE GRADING WORK HAS BEEN COMPLETED AT THIS TIME. THIS SITE WILL BE RECHECKED NEXT WEEK TO SEE IF THEY ARE READY FOR THE FINAL INSPECTION OF THE GRADING PERMIT. CURRENTLY THE CONTRACTOR IS WORKING ON THE PLACEMENT OF THE DECOMPOSED GRANTED IN ALL AREAS THAT HAVE BEEN DISTURBED. THE STATUS OF THIS INSPECTION WILL NOT CHENGE UNTIL ALL OF THE EXTERIOR WORK IS COMPLETE AND THE SITE IS FINALED. | |
07/09/2009 | GRADING - FINAL | Partial Approval | I WALKED THE SITE TO SEE WHAT ITEMS HAVE BEEN COMPLETED AT THIS TIME FOR THE RELEASE OF THE GRADING PERMIT. ONLY BLDG 1 HAS BEEN COMPLETED AT THIS TIME, BUILDINGS 2 AND 3 HAVE NOT BEEN STARTED, THE PADS HAVE BEEN GRADED ONLY. THE FOLLOWING ITEMS HAVE BEEN DISCUSSED AS BEING INSUFFICIENT AND WILL NEED TO BE ADDRESS PRIOR TO REQUESTING THE FINAL INSPECTION FOR THE CLOSING OF THE PERMIT: 1) THE TRASH ENCLOSURES HAVE BEEN CONSTRUCTED PER THE DETAIL IN THE APPROVED PLANS BUT ARE JUST UNDER 10 FEET OF CLEAR OPEN SPACE BETWEEN THE GATE AND THE BOLLARDS ALONG THE BACK WALL. 2) THE PED STRIPING LOCATED AT THE SOUTHEAST CORNER OF BLDG #1 TO THE TRASH ENCLOSURE HAS NOT BEEN COMPLETED AT THIS TIME. 3) THE TRASH ENCLOSURE LOCATED AT THE NORTHEAST CORNER OF BLDG #1 SOUTH OF BLDG #2 IS MISSING THE SIDEWALK ALONG THE EAST SIDE OF THE ENCLOSURE AS WELL AS THE BIKE PARKING ENCLOSURE. 4) THE ORIFICE PLATE THAT IS TO BE INSTALLED ONTO OUTLET PIPE OF THE RETENTION/DETENTION BASIN IS MISSING AT THIS TIME. 5) THERE IS MISSING HANDRAIL ALONG THE BASINS LOCATED ON THE NORTH SIDE OF THE PROJECT. 6) ROCK RIP RAP IS MISSING IN THE WESTERN BASIN AT THE SOUTHWEST CORNER OF THE BASIN. A 30' RADIUS HAS BEEN SPECIFIED BUT HAS NOT BEEN PROVIDED AT THIS TIME. 7) THE SIDEWALK HAS BEEN CHANGED ALONG THE EAST SIDE OF THE NORTH ENTRANCE OFF OF GOLF LINKS ROAD, THESE ALONG WITH ANY OTHER CHANGES THAT HAVE BEEN MADE TO THIS SITE WILL NEED TO BE ADDED TO THE "AS-BUILT DRAWINGS" FOR THIS SITE PRIOR TO THE COMPLETION OF THE PROJECT AND CLOSING OF THE CURRENT GRADING PERMIT. 8) THE 6" VERTICAL CURB SOUTH OF THE RETENTION / DETENTION BASINS HAVE NOT BEEN CONSTRUCTED PER THE APPROVED PLANS. THIS ITEM HAS BEEN ELIMINATED FROM THE SITE, THE DEVELOPER HAS INTERN UTILIZED THE RETAINING WALL AS THEIR VERTICAL CURB. THE ENGINEER OF RECORD WILL NEED TO MAKE THESE APPROVED CHANGES ONTO THE APPROVED PLANS PRIOR TO FINALLING THE PROJECT COMPLETELY. |