Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA FINAL/BARRIER
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/29/2008 | POOL/SPA FINAL/BARRIER | Approved | IVRS - Inspection :* 1) NO SVRS REQUIRED 2) INSURE CAP FROM VACUUM BREAKER LINE IS REMOVED |
|
| 08/27/2008 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FENCE WITHIN 5' OF WATER MUST BE BONDED 2) LABEL BREAKERS IN POOL SUB PANEL 3) NO SVRS REQUIRED |
|
| 08/26/2008 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LABEL ALL CIRCUITS IN POOL PANEL 2) BOND METAL FENCE TO MAIN POOL BOND GRID (NOT DECK BOND GRID) 3) USE BELL COVERS FOR RECEPTS. YOU MUST BE ABLE TO PLUG IN CORD AND CLOSE THE WEATHER PROOF COVER 4) WAS A & A DRAIN SYSTEM INSTALLED ? PLAN IS NOT STAMPED, NO 2" VACUUM VENT AT POOL DECK. INSTALL SVRS UNIT 5) NO MORE THAN 4" GAP AT BOTTOM OF FENCE 6) SUPPORT H20 LINE AT ANTI-SIPHON/VERTICAL |
|
| 08/25/2008 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WHEN GATE IS RELEASED FROM 1' OPEN IT DOES NOT LATCH |
|
| 08/19/2008 | POOL/SPA FINAL/BARRIER | Cancelled | ||
| 08/19/2008 | POOL/SPA FINAL/BARRIER | Not ready for Inspection | IVRS - Inspection :* | |
| 07/15/2008 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 07/11/2008 | POOL/SPA FINAL/BARRIER | Not ready for Inspection | IVRS - Inspection :* |