Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA ELECTRIC
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/12/2008 | POOL/SPA ELECTRIC | Approved | IVRS - Inspection :* | |
| 08/08/2008 | POOL/SPA ELECTRIC | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED GFCI PROTECTION ON FOR RECEPT. PORCH 2) LEAVE LISTING FOR COMPOUND USED ON BOND CONNECTION IN WET NICHE FIXTURE 3) LEAVE HEATER INSTALL INSTRUCTION, T & P VALVE NOT INSTALLED PER MANUFACTURER INSTRUCTION ON LABEL ATTACHED TO VALVE 4) TOOK ? MANUAL WITH ME I WILL RETURN IT, I NEED TO VERIFY IF IT IS APPROVED FOR USE BY THE CITY 5) BOND JUNCTION BOX, HOUSE WIRING TO POOL LIGHT 6) REAR GATE DOESN'T SELF CLOSE |
|
| 07/23/2008 | POOL/SPA ELECTRIC | Not ready for Inspection | IVRS - Inspection :* | |
| 07/09/2008 | POOL/SPA ELECTRIC | Partial Approval | IVRS - Inspection :* |