Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T08BU00842

Parcel: 11615088L


Addresses:

395 N SILVERBELL RD


Inspection Status: Approved

Inspection History: ENGINEERING PRE-CONSTRUCTION

Permit Number - T08BU00842

Inspection Description - ENGINEERING PRE-CONSTRUCTION

Inspection Status - Approved

Date Description Inspector Results Comments
07/17/2008 ENGINEERING PRE-CONSTRUCTION Approved MET WITH SUPINTENDENT (JIM W/DIVERSIFIED). SITE IS > 1 ACRE AND HAS A SWPPP.

1) PROVIDE AS-BUILT W/ SURVEYED INVERT AND PIPE DATA AT END OF CONSTRUCTION.
2) PROVIDE AN APPROVED REVISION FOR ANY SIGNIFICANT CHANGES MADE TO THE ORIGINAL APPROVED GRADING PLAN.
3) PRIOR TO FINAL GRADING APPROVAL, PROVIDE A CERTIFIED STATEMENT FRON THE ENGINEER OF RECORD STATING THAT ALL DRAINAGE WAYS AND RET/DET BASINS HAVE BEEN CONSTRUCTED PER THE APPROVED PLAN.
4) REDLINE APPROVED CHANGES TO THE SWPPP DRAWING AS NEEDED.
5) PERFORM ROUTINE STORM WATER SELF INSPECTIONS AND MAINTENANCE PER YOUR PLAN AND DOCUMENT THEM.
6) INSTALL AND MAINTAIN A STABILIZED CONSTRUCTION ENTRANCE/EXIT PER PLAN.
7) INSTALL A DESIGNATED CONCRETE/MATERIALS WASH-OUT WHEN APPLICALBLE.
8) SWEEP UP ALL TRACKED MATERIAL OFF OF PUBLIC ROADWAYS ROUTINELY.
9) PROVIDE AND POST A COPY OF YOUR NOI ON SITE PER AZPDES.