Permit: T08BU00806

Parcel: 131010280


Addresses:

4880 E 22ND ST

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
09/29/2008 MECHANICAL - FINAL Approved IVRS - Inspection :*
08/13/2008 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
INTERLOCK MAKE UP AIR WITH EXHAUST FAN
PROVIDE DISCONNECT FOR EXHAUST FAN ON ROOF
OK TO INSTALL ANSUL SYSTEM
06/04/2008 MECHANICAL - FINAL Not ready for Inspection IVRS - Inspection :*
06/02/2008 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
EXHAUST FAN NOT PROPERLY SECURED & NOT ON A CURB
NEED MECH. CONTRACTOR ON SITE FOR NEXT INSPECTION
05/12/2008 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. KITCHEN EXHAUST FAN MUST DISCHARGE 10' AWAY
OR 2' ABOVE AN INTAKE INTO THE BUILDING INCLUDING
MAKE UP AIR
2. KITCHEN EXHAUST FAN DOES NOT HAVE GREASE TROUGH AT ROOF
05/09/2008 MECHANICAL - FINAL Not ready for Inspection IVRS - Inspection :*