Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA PRE-GUNITE
Permit Number - T08BU00646
Inspection Description - POOL/SPA PRE-GUNITE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/02/2008 | POOL/SPA PRE-GUNITE | Approved | IVRS - Inspection :* | |
05/01/2008 | POOL/SPA PRE-GUNITE | Partial Approval | IVRS - Inspection :* 1) PENDING CORRECTION OF GROUND CLAMPS 2) CLAMP APPROVED FOR BURIAL IN CONCRETE IS REQUIRED FOR GROUND WIRES. THESE KEEP THE COPPER WIRE FROM TOUCHING THE REBAR 3) CONDUIT TO LIGHT OK 4) AN INSPECTED BONDING LOOP WILL BE REQUIRED PRIOR TO DECK POURING 5) ALL GATES IN ENCLOSURE/BARRIER MUST OPEN OUT AND BE SELF CLOSING AND LATCHING AND 5' HIGH FROM OUTSIDE |