Permit: T08BU00473

Parcel: 140062510


Addresses:

3836 E DOVER SV

Inspection Status: Approved

Inspection History: POOL/SPA ELECTRIC

Date Description Inspector Results Comments
09/08/2008 POOL/SPA ELECTRIC Approved IVRS - Inspection :*
07/30/2008 POOL/SPA ELECTRIC Not ready for Inspection IVRS - Inspection :*
1) LAST INSPECTION WAS CHAIN LINK APPROVED WITH XMAS TREE BRANCHES ?
2) BOND ALL METAL FENCES WITH IN 5'-0" OF H20 LINE
3) #14 CU ON 20 AMP BREEAKER ROMEX, MOVE AWAY FROM HOT BUSS IN SERV.
4) USE ONLY SQUARE 'D' BREAKERS, SEE SERVICE LABEL
5) ROMEX NEEDS TO BE IN CONDUIT
6) SVRS #027340
07/09/2008 POOL/SPA ELECTRIC Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. NEED TO FINISH MAIN SERVICE PANEL & COMPLETE WIRING TO POOL EQUIP.
TO BE ABLE TO IDENTIFY POWER TO POOL EQUIPMENT
2. OPENING UNDER BOTTOM RAIL OF FENCE MIN. 4"
NEED TO BE LANDSCAPED OR FILLED FOR FINAL
3. MISSING VACUUM RELIEF SYSTEM
4. PLANS CALL FOR REMOVAL OF CHAIN LINK FENCE TO BE REPLACED WITH WOODEN FENCE
BARRIER USED WITH IMITATION X-MAS TREE BRANCH NOT APPROVED METHOD
05/09/2008 POOL/SPA ELECTRIC Partial Approval IVRS - Inspection :*
RECALL 08035 PRIOR TO KOOL DECK POUR TO VERIFY COMPLETION OF BONDING LOOP
05/01/2008 POOL/SPA ELECTRIC Denied IVRS - Inspection :
See detailed listing on site.| 999*