Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA PLUMBING
Permit Number - T08BU00124
Inspection Description - POOL/SPA PLUMBING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/21/2008 | POOL/SPA PLUMBING | Approved | IVRS - Inspection :* | |
05/20/2008 | POOL/SPA PLUMBING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DRAIN COVERS NOT ON SITE 2) BOND BARRIER WITHIN 5' WATERS EDGE 3) BOND PUMP 4) WIRNG TO HEATER NOT COMPLETE 5) BARRIER NOT PER PLAN MUST CONTAIN POOL 6) HOUSE MAY NOT BE USED AS BARRIER 7) GATES LEADING TO POOL AREA MUST SELF LATCH, SELF CLOSE 8) SVRS #027351 |
|
04/09/2008 | POOL/SPA PLUMBING | Not ready for Inspection | IVRS - Inspection :* | |
03/10/2008 | POOL/SPA PLUMBING | Partial Approval | IVRS - Inspection :* 1) POOL AREA ONLY |
|
03/06/2008 | POOL/SPA PLUMBING | Not ready for Inspection | IVRS - Inspection :* | |
03/05/2008 | POOL/SPA PLUMBING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE DETAIL FOR NEGATIVE EDGE STEEL LAYOUT 2) POOL NOT IN LOCATION SHOWED ON APPROVED SITE PLAN 3) REVISE SITE PLAN OR BUILD TO PLAN-SITE PLAN TO SHOW WASHES ON PROPERTY 4) STOPPED INSPECTION |