Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T08BU00007

Parcel: 12215163A


Addresses:

3150 E GRANT RD


Inspection Status: Approved

Inspection History: GRADING - FINAL

Permit Number - T08BU00007

Inspection Description - GRADING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
08/12/2008 GRADING - FINAL Approved
08/07/2008 GRADING - FINAL Denied 1) PROVIDE A CERTIFICATION STATEMENT FRON THE ENGINEER OF RECORD STATING THAT THE DRAINAGE WAYS AND RET/DET BASINS ON SITE WERE BUILT IN ACCORDANCE WITH THE APPROVED PLAN.
2) PROVIDE CLARIFICATION FROM THE ENGINEER OF RECORD ON FLOW DIRECTION OF STORM WATER IN THE RET/DET BASIN LOCATED ON THE EAST SIDE OF THE SITE.
3) ENSURE THE EAST BASIN DRAINS OUT THE WALL OPENINGS TO THE SOUTH AND NOT IN THE DOOR OF THE ADJACENT BUSINEES TO THE NORTH.
4) ENSURE THE EAST RET/DET BASIN DOES NOT HOLD WATER >24 HOURS.