Permit: T07PL02217

Parcel: 122184980

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T07PL02217

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
01/18/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
GAS PIPE OK
OK FOR GAS
UCC LEFT AT METER
01/04/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- IDENTIFY PIPING AT METER LOCATION AND ID FURNACE WITH UNIT #
- SUPPORT PIPING ON ROOF
- TEST AT 10 PSI
- INSTALL FLASHINGS AT ROOF PENETRATIONS
- REMOVE SHARP BURRS FROM UNISTRUT
01/02/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE ACCESS TO THE ROOF
A. GAS PIPE TO BE SUPPORTED IN AN APPROVED MANNER
B. GAS PACK REQUIRES SEDIMENT TRAP
C. MAKE ALL CONNECTIONS DO NOT TEST THRU APPLIANCE
2. AN ADULT MUST BE PRESENT TO ASSIST INSPECTOR

CONTINUED "NOT READY" WILL RESULT IN A
REINSPECTION FEE