Permit: T07PL02216

Parcel: 116131470


Addresses:

614 N SAN RAFAEL AV

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
01/18/2008 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
01/17/2008 PLUMBING - GAS PRESSURE TEST Partial Approval IVRS - Inspection :*
1. MAKE ALL CONNECTIONS HOOK UP ALL APPLIANCES
TEST ENTIRE SYSTEM. DO NOT TEST THRU APPLIANCES.
2. OK TO COVER UNDERGROUND
3. ALL VALVES TO BE AGA OR CSA APPROVED
4. FURNACE AND WATER HEATER REQUIRE SEDIMENT TRAPS
5. WATER HEATER WILL REQUIRE UPGRADES WHEN IT IS REPLACED.
01/04/2008 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1. PROVIDE MINIMUM 10 PSI TEST AT TIME OF INSPECTION
2. ALL FITTINGS & TOOL MARKS TO BE PRIMED THEN TAPED TO MEET 40 MIL. THICKNESS OF TAPE ON ALL UNDERGROUND FITTINGS AND TOOL MARKS
3. NEED ACCESS TO ENTIRE GAS SYSTEM

NOT COMPLETE LIST