Permit: T07PL02108

Parcel: 127041910


Addresses:

5026 E ROSEWOOD ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESS TEST FNL

Date Description Inspector Results Comments
02/11/2008 PLUMBING - GAS PRESS TEST FNL Approved IVRS - Inspection :*
02/08/2008 PLUMBING - GAS PRESS TEST FNL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- FLASHING REQUIRED AT ROOF PENETRATION. RETEST.
- SHUT OFF VALVE REQUIRED AT BUILDING W/REMOTE METER LOCATION
- SUPPORTS REQUIRED ON ALL PIPING AT BRANCH CONNECTIONS, APPLIANCE CONNECTIONS AND NOT TO EXCEED 8'
- USE TREATED LUMBER OR WEATHER RESISTANT SUPPORTS
- SEDIMENT TRAPS REQUIRED AT FURNACES AND WH
- 1" CLEARANCE REQUIRED AROUND B VENT
- SECURE UNISTRUT AND USE UNISTRUT CLAMPS WHERE UNISTRUT IS USED
- AGA VALVE NEEDED AT STOVE
- OK TO COVER YARD PIPING