Permit: T07PL02101

Parcel: 126134310


Addresses:

4519 E DOUGLAS ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/18/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
GAS CARD AT METER
12/17/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
SEE NOTE #3 AND FOLLOWING NOTE ON THIS INSPECTION SHEET DATED 12/11/07 AND COMPLY TO OBTAIN GAS CLEARANCE CARD.
12/11/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SHALL PROVIDE SEDIMENT TRAPS AT GAS ENTRY TO WATER HEATER & FURNACE
2. WATER HEATER DRAFT HOOD TO BE INSTALLED CORRECTLY
3. VENT FROM FURNACE & WATER HEATER TO BE INSTALLED CORRECTLY, SIZED PROPERLY AND HAVE APPROVED VENT CAP 3' MINIMUM ABOVE TOP OF COOLER INTAKE.

NOTE: LARGEST BTU DEMAND DEVICE TO BE VENTED SIZED PROPERLY WITH SMALLER BTU DEMAND DEVICE TYING IN ABOVE IT WITH CORRECT APPROVED VENT FITTINGS WITH
3-GALV SCREWS AT ALL JOINTS. SINGLE TO DOUBLE WALL VENT CONNECTION TO HAVE NO TAPE, SHALL BE OPEN FOR DRAFT SPACE.