Permit: T07PL02043

Parcel: 134042520


Addresses:

366 S GOLLOB RD

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/10/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
CORRECTIONS HAVE BEEN MADE
12/07/2007 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
- PROVIDE APPROVED PRIMER ON ALL JOINTS AND TOOL MARKS PRIOR TO APPLYING 2 LAYERS OF 10 MIL TAPE WITH 1/2" OVERLAPS.
- LEAVE CAN OF PRIMER ON SITE
- 10 PSI TEST IS OK
- LEFT GAS CARD
- DO NOT BACKFILL TRENCH - RECALL FOR FINAL
12/06/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- SCOTCH COATED PIPE MUST BE USED FOR ALL BURIED PIPE.
- PRIMER & TAPE ALL FITTINGS & TOOL MARKS
- PIPE PASSING THROUGH MASONRY MUST BE PROTECTED
- PROVIDE MIN. 3 SCREWS IN ALL JOINTS OF WATER HEATER VENT CONNECTOR.