Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/10/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* CORRECTIONS HAVE BEEN MADE |
|
| 12/07/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* - PROVIDE APPROVED PRIMER ON ALL JOINTS AND TOOL MARKS PRIOR TO APPLYING 2 LAYERS OF 10 MIL TAPE WITH 1/2" OVERLAPS. - LEAVE CAN OF PRIMER ON SITE - 10 PSI TEST IS OK - LEFT GAS CARD - DO NOT BACKFILL TRENCH - RECALL FOR FINAL |
|
| 12/06/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - SCOTCH COATED PIPE MUST BE USED FOR ALL BURIED PIPE. - PRIMER & TAPE ALL FITTINGS & TOOL MARKS - PIPE PASSING THROUGH MASONRY MUST BE PROTECTED - PROVIDE MIN. 3 SCREWS IN ALL JOINTS OF WATER HEATER VENT CONNECTOR. |