Permit: T07PL01968

Parcel: 113061000


Addresses:

1355 E LIND RD

Inspection Status: Denied

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
01/14/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- GAUGE READING ZERO.
- PROVIDE AN AIR PRESSURE TEST ON SYSTEM
- EXTEND TYPE B VENTS FROM WATER HEATER AND FURNACES TO TWO FEET ABOVE COMBUSTION AIR OPENING.
- PROVIDE ELECTRICAL BONDING OF GAS SYSTEM
- SUPPORT PIPING AT METER AND AT FURNACES.
- ROUTE PIPING IN FRONT OF FURNACES BUT ALLOWING ACCESS BEHIND PANEL AND CLEARANCE FROM OTHER PIPING
- RECONNECT CONDENSATE PIPING DISASSEMBLED DURING CONSTRUCTION. CAP OLD PIPING.
11/21/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*