Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/22/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* CORRECTIONS HAVE BEEN MADE |
|
| 11/14/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* PROVIDE DOUBLE WALL VENT PIPE FOR WATER HEATER. USE AN APPROVED CAP & ROOF JACK RECALL FOR INSPECTION LEFT GAS CARD EVERYTHING ELSE OK |
|
| 11/13/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE PERMIT FOR NEW WH AND FURNACE 2) CORRECT FLUE, B-VENT REQUIRED 3) SECURE WITH SCREWS 4) HARD PIPE T & P 5) INSTALL SEDIMENT TRAP 6) WRAP TOOL MARKS ON SCOTCH KOTE 7) SECURE ATTIC PIPING WITH TWO HOLE STRAPS 8) PROVIDE ELECTRICAL BONDING |