Inspection History Details
Inspection Status: Denied
Inspection History: PLUMBING - FINAL
Permit Number - T07PL01913
Inspection Description - PLUMBING - FINAL
Inspection Status - Denied
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/14/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* TEST W/15 PSI GAUGE CORRECT FURNACE VENT PROVIDE A LADDER TO INSPECT VENT TERMINATION PROVIDE COMBUSTION AIR OPENINGS |
|
02/06/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - PROVIDE A PRESSURE TEST USING A 15 PSI GAUGE - RECALL FOR INSPECTION WHEN TEST IS IN PLACE - RECALL FOR INSPECTION WHEN YOU HAVE REMOVED ALL RAW SEWAGE FROM METER LOCATION AND AFTER CORRECTING OPEN SEWER - NOTE: ALL PLUMBING WORK REQUIRES PERMITS ABS IS NOT APPROVED FOR USE ABOVE GRADE AND EXPOSED TO SUNLIGHT. |
|
01/18/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* |