Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T07PL01865

Parcel: 132092410


Addresses:

2929 S FORGEUS AV

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
11/28/2007 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
GAS CARD ON PIPE AT METER
11/23/2007 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1. SHALL PROVIDE APPROVED COUPLINGS (NOT THREAD PROTECTORS)
2. ALL TOOL MARKS & FITTINGS UNDERGROUND TO BE PRIMED THEN TAPPED
3. SHALL PROVIDE AGA OR CSA APPROVED GAS SHUT OFF VALVE AT BUILING SERVICE ENTRY
4. WATER HEATER TO BE INSTALLED CORRECTLY AND SHALL HAVE UPPER COMBUSTION AIR TO EQUAL 100 SQ. INCHES
5. WATER HEATER TEMPERATURE & PRESSURE RELIEF SHALL GRAVITY DRAIN TO DAYLIGHT OR PROVIDE PETITION OF APPEAL FOR ALTERNATE FORM OF TEMPERATURE & PRESSURE RELIEF SIGNED BY CITY ON SITE WITH CORRECT INSTALLATION.
6. PROVIDE BONDING OF BUILDING GAS SYSTEM
7. PROVIDE SEDIMENT TRAP FOR WATER HEATER & FURNACE

125 PSI PRESSURE RELIEF DEVICE
11/20/2007 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. NO ONE HOME UNABLE TO INSPECT INSIDE HOME
2. PLEASE HAVE ADULT HOME FOR INSPECTION THANK YOU
11/13/2007 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GAS TEST HAS 2 POUND 10 REQUIRED
2) PTR LINE SHALL DISCHARGE DOWNWARD INTO A PAN 6" FROM FLOOR
11/06/2007 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
NO ONE AT HOME UNABLE TO DO INSPECTION
11/02/2007 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
PLEASE MAKE ADDRESS VISIBLE
EXPOSE REPAIR
PROVIDE A 10 PSI PRESSURE TEST WITH A 15 PSI GAUGE
PROVIDE ACCESS TO APPLIANCES