Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T07PL01851
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/04/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
02/14/2008 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* ORIGINAL WH WAS GAS. NEW WH IS ELECTRIC. WIRING APPEARS TO HAVE BEEN INSTALLED W/OUT INSPECTION. PROVIDE AN ELECTRICAL PERMIT FOR NEW WIRING. |
|
02/06/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* I WILL NOT DO THIS INSPECTION WITH RAW SEWAGE ON THE GROUND! CORRECT SEWER, INSTALL AN APPROVED CAP AND CLEAN THIS MESS IMMEDIATELY! |
|
12/05/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - WATER CONNECTORS ARE LEAKING - BLACK IRON PIPING NOT APPROVED FOR POTABLE WATER - PIPE T&P TO 6"-24" ABOVE FLOOR AND W/APPROVED MATERIAL - MAKE UP CONDUIT JOINTS COMPLETELY AND TIGHTEN - REMOVE DIRT AGAINST WH |
|
10/31/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. WATER HEATER TO BE ON APPROVED FIRM BASE 2. ELECTRIC TO BE CONNECTED TO APPLIANCE CORRECTLY 3. TEMPERATURE & PRESSURE RELIEF TO BE TERMINATED CORRECTLY |