Permit: T07PL01842

Parcel: 136202730


Addresses:

8165 E DOMENIC ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
01/03/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
12/05/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
OTHER ITEMS ABOVE OK
CORRECT VENT AT FURNACE PRIOR TO OPERATION
11/05/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
GAS CARD AT METER
1. SHALL PROVIDE BONDING OF BUILDING GAS PIPING
2. SHALL PROVIDE SEDIMENT TRAP AT GAS ENTRY TO WATER HEATER
3. PROVIDE 3-GAL SCREWS AT EACH JOINT OF WATER HEATER VENT PIPNG
4. MAKE ROOF PENETRATION WEATHER TIGHT
5. SUPPORT & SECURE GAS DROPS AT FURNACE & WATER HEATER
11/02/2007 PLUMBING - FINAL Cancelled