Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T07PL01809

Parcel: 116211080

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
11/09/2007 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
11/08/2007 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
11/06/2007 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
10/31/2007 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1. PRESSURE TEST NOT HOLDING
2. PROVIDE MIN. 10 PSI TEST
3. REPAIR LEAK BEFORE CALLING FOR INSPECTION
10/30/2007 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
10/27/2007 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*