Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07PL01782

Parcel: 136330830


Addresses:

9273 E 39TH ST


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T07PL01782

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
10/30/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
GAS CARD AT METER

WEATHER SEAL YOUR ROOF FLASHINGS WHERE PIPE PENETRATES ROOF - SW GAS 889-1888
10/22/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SUPPORT GAS PIPING AT METER LOCATION
2. PROVIDE FLASHING FOR ALL PIPE PENETRATIONS THRU ROOF AND THEY SHALL BE WEATHER TIGHT
3. PROVIDE AGA OR CSA LISTED GAS APPLIANCE SHUT OFF VALVES AT APPLIANCES
(3090)
4. SUPPORT GAS PIPING AT ROOFTOP UNIT
5. SUPPORT GAS PIPING AT WATER HEATER VALVE
6. WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN TO BE RIDGID FULL SIZE PIPE GRAVITY DRAINING (NO FLEX)
7. PROVIDE SEDIMENT TRAP AT GAS ENTRY TO WATER HEATER & FURNACE

RETEST & RECALL INSPECTION