Permit: T07PL01769

Parcel: 136083040


Addresses:

2421 S KEVIN DR

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/01/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
SW GAS 889-1888
10/29/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELLED
10/26/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
READ & COMPLY WITH NOTES ON THIS INSPECTION
10/24/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. GAS PIPING SYSTEM TO BE TESTED IN ITS ENTIRETY, WITH MINIMUM 10 PSI TEST WITH NO LOSS OF PRESSURE FOR 15 MINUTES.
2. SECURE GAS PIPING AT DROP TO DRYER
3. EXPOSE METER AREA OF PIPING AND ENTIRE AREA FROM REPAIR TO BUILDING ENTRY, PROVIDE PRIMER THEN 10MIL TAPE ALL TOOL MAKRS, FITTINGS AND UNCOATED PIPE.
4. PROVIDE BONDING OF BUILDING GAS PIPING
5. REATTACH THE GROUND CLAMP TO BUILDING HOSE BIB AT REAR GAS SERVICE ENTRY.
10/16/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
12:56 NO ACCESS, PLEASE HAVE AN ADULT PRESENT TO PROVIDE ACCESS AT REINSPECTION