Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/30/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 10/24/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SEE NOTE #1 FROM 10/22/07 INSPECTION AND COMPLY, IF YOU INSTALL DOUBLE WALL VENT PIPING IT SHALL BE DOUBLE WALL TO POINT OF TERMINATION. DRAFT SPACE IS TO BE KEPT OPEN. 2. CAP DRYER GAS ON VERTICAL STUB UP ON EXTERIOR OF DRYER CLOSET IF GAS IS NOT DESIRED AT THIS LOCATION. |
|
| 10/22/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. SHALL PROVIDE APPROVED TRANSITION FITTING FOR VENT FROM FURNACE AND MINIMUM CLEARANCE FROM SINGLE WALL VENT PIPING 6" FROM COMBUSTIBLES, 1" CLEARANCE FROM COMBUSTIBLES FOR DOUBLE WALL VENT PIPING 2. PROVIDE RIDGID NIPPLE THRU FURNACE APPLIANCE HOUSING 3. SUPPORT GAS PIPING & SECURE AT DRYER LOCATION |
|
| 10/12/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* PRESSURE TEST NOT HOLDING |