Permit: T07PL01746

Parcel: 122152790


Addresses:

3329 E SENECA ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/24/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
CORRECTIONS MADE OK
OK FOR GAS

SW GAS 889-1888
10/18/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. ROOF PENETRATION REQUIRES AN APPROVED FLASHING (ROOF JACK)
2. ROOFTOP GAS TO BE SUPPORTED 3 1/2" ABOVE ROOF AND BLOCKED EVERY 10'
3. WILL REQUIRE TEST ON SYSTEM
4. USE 15# TEST GAUGE IN 1/10LB INCREMENTATION
TEST AT 3 OR MORE POUNDS.
5. SEDIMENT TRAP REQUIRED AT UNIT